G-6 Summary of fault analysis
There were issues that arose during testing that have need of fixing; these issues
pertaining to the locking mechanism, the accelerometer, and the power system. There is a safety
concern with the locking mechanism that is partly taken care of by the removable cable. When
the system battery dies the DLA is not able to function to unlock the cable from the lock
housing, this presents the issue of the cable getting tangled in either the spokes, or the chain on
the bicycle while riding. Because of this issue it would be suggested that a second key cylinder
be incorporated into the locking mechanism to make the cable removable even during instances
of power failure and would make the system safer, as well as making it usable as a physical
deterrent should the user not have charged the CABL.
The accelerometer has complications with detecting movement if the circuit is not set
level. This issue is fixed by securing the accelerometer level at a specific angle but due to the
different angles of bicycle frames the CABL may not be overly-sensitive. To fix this issue
multiple accelerometers may be used but this increases power requirements and takes up much
needed space.
The last known issue is that of the power system. When the system is active the voltage
regulators begin heating up. The voltage regulators must down step the voltage to 5 volts by
dissipating the extra power as heat. This heat continues to build up until the regulators over heat
and stop functioning. This is a major issue because if the regulators stop functioning the control
circuit shuts down and the system will no longer work. There are a few ways of dealing with this
issue; the first and simplest of which is to add in a second battery. This battery would have to
power the control circuit and the accelerometer all the time and would probably die rather
quickly. The second option would be to add in a source of cooling such as a larger heat sink, a
liquid cooling system or possibly even a fan which would require more power and a lot of space.